3 size of leader required.
Roof drain sizing.
Conventional gutter systems such as those used on most houses are suitable for some low slope roofs.
1 rate of precipitation.
The full flow capacity of a drain is not realized until the water reaches approximately 2 5 above the inlet in a four inch drain and 3 5 in a six inch drain.
The four things you will need to know are.
When sizing roof drains the limiting factor for the amount of water each drain will carry away is the size of leader therefore increasing leader size decreases the number of drains required.
The result is the number of drains needed.
And then determine from the chart below how many roof drains you require.
How to measure roof drain parts.
2 total area of roof.
Designers specify compliance with bs en 12056 3 2000 that includes a calculation for the allowable capacity of the rainwater pipes.
According to the chart for 1 8 slope per 12 of pipe for 5 000 square feet of roof area with a 6 per hour of rainfall the required pipe size is 8.
Take the roof s total square footage and divide by the total square footage handled by one drain.
1 in 25 4 mm 1 ft 305 mm 1 ft2 0 0929 m2 100 0 figure a101 1 example roof plan 4 a 101 2 solution.
Each 4 drain size in a 6 hourly rainfall area will accommodate drainage of 3 070 sq.
The rain storm the flow of rainwater on the roof surface the ability of the roof drain to move the water from the roof to the piping the vertical piping the horizontal piping and the connection to the point of discharge.
Area roof will require 100 000 3070 32 5 or 33 roof drains for ideal drainage.
50 000 4 400 11 36.
Zurn makes it easy to size roof drains.
Or 12 drains required.
The roof drain or gutter or drain piping or downspout leader size diameter other size constraints e g.
The first step in sizing a roof drain is to calculate the surface area of the roof that the.
For example in the u k.
Factors which affect proper roof drainage are deck slope drain size and placement of drains.
Therefore the 100 000 sq.
The sizing of the roof drainage system must consider all components.
Click the table headings to sort by that column.
To size the vertical roof drain for the same parameters 5 000 square feet of room area and 6 per hour of rain consult table 1106 2 figure 3.
And 4 area handled by each drain.
The sizing of roof drains must be large enough to quickly carry away all water entering the roof drains.
Product name manufacturer color bolt hole style lip to lip bolt to bolt 180 bolt to bolt bolt holes type of bolt used material.